Tuesday, May 28, 2019

Huba Control Heat sink

Heat sink



As a result of the heat sink it is possible to use medium with higher temperature. The cooling section reduces the temperature of the hot media. Depending on the ambient temperature the use of medium with temperature of more than 200°C without harming the transmitter is possible. Different standardised pressure connections allow the combination with the pressure measurement systems of Huba Control.




Medium 
Liquids and gases
Material 
Stainless steel 1.4305 / AISI 303
Media duct 
Ø 4mm
WeightApprox. 325g

Favourable solution for high media temperatures
Easy mounting



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 

Huba Control Digital Indicating Device 801

Digital Indicating Device 801
LCD Module


Type 801 digital indicators are compatible with all sensors with DIN plug EN 175301-803-A.  Independent of the mounting position of the sensor, the display can be rotated to give the ideal reading position. The 801 has a 3 digit liquid-crystal display which is adjustable by the customer, or available factory set.




Input signals 0 ... 5 V
                                                  0 ... 10 V
                                                  0 ... 20 mA

                                                  4 ... 20 mA

Portable plug-in indicator

Irrespective of the installation arrangement of your transducer the display module can be rotated and turned to give the ideal reading-position

Protection class IP 65 with screw fastened DIN EN 175301-803 connectors




Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia.

Huba Control Digital Indicating Device 800

Digital Indicating Device 800
mbar / bar with 2 limit values

Type 800 digital indicators are equipped with a 4 digit display, as well as optional switch and analogue outputs. The sensor signal is evaluated and indicated as pressure by the digital display. The programming of the limit value output can be executed with the buttons on the front or via a data cable from a computer.




Input signals 
0 ... 5 V, 0 ... 10 V,
0 ... 20 mA, 4 ... 20 mA
Output signals0 ... 10 V,
0 ... 20 mA, 4 ... 20 mA
Potential-free limit value switch



Accessories
Protection cover
800.100
Data cable
 800.200



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 





Huba Control Force cell 410

Force cell 410
40 to 265 Centi-Newton

The type 410 measures force with the cantilever beam by an integrated piezo-resistive wheatstone bridge with front-end amplification circuit. It uses hybrid thick film technology which guarantees an excellent stability and a long operating life. The special design of the force cell ensure batch production and with fully automated assembly an ideal performance to cost ratio for high quantities. Fixed order quantities on request




Measuring range 
0 ... 53 – 265 Centi-Newton
Output 
0.3 ... 2.8 V
Electrical connection 
PIN connection, RAST 2.5
CompensationWith temperature compensated

Compact construction for a wide range of industrial applications
Ideal for OEM batches in high quantities
High resistance to extreme temperatures
No mechanical aging
No mechanical creepage



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 

Huba Control Pressure measuring cell 513 - barometric sensor

Pressure measuring cell OEM 513 - barometric sensor
0.8 ... 1.4 bar


This pressure measuring cell, barometric adjusted with protection case is suitable for plug mounting on PCB. The output signal is linear, temperature compensated and amplified. The robust construction guarantees a long term stable measuring result. Fixed order quantities on request




Medium 
Air and neutral gases
Pressure range 
0.8 ... 1.4 bar
Output 
ratiom. 10 ... 90%
Accuracy 
< 0.3 % FS
Electrical connectionConnector RAST 1.27 mm

Integrated amplifier electronics
No customer specific adjustment necessary
Excellent EMC capacity by reinforcement on measuring cell
Easy and quick fitting
Plastic case for direct mounting


Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 

Huba Control Pressure measuring cell 513

OEM Pressure measuring cell 513
-1 ... 0 - 600 bar

Type 513 pressure measuring cells have an adjusted, amplified sensor signal. They are especially suitable for high quantities in OEM applications. The unique integrated electronics allow installation without the need for temperature and pressure adjustment by the customer. Fixed order quantities on request




Medium Liquids and gases
Pressure range -1 ... 0 – 600 bar
Output ratiom. 10 ... 90%, ratiom. 10 ... 60% ± 1.2 V
Accuracy < 0.3% FS
Electrical connectionFlexible connector RAST 2.54 mm,
connector RAST 1.27 mm

Integrated amplifier electronics
No customer specific adjustment necessary
Excellent EMC capacity by reinforcement on measuring cell
Easy and quick fitting
Negligible temperature influence on accuracy

Accessories
O-Ring FPM -15 ... +125 ºC
105598
O-Ring NBR -25 ... + 85 ºC
105145
O-Ring FPM -30 ... +150 ºC
109338
O-Ring FPM -15 ... +125 ºC
 105285
O-Ring NBR -25 ... + 85 ºC
 104952
O-Ring FPM -30 ... +150 ºC
102321
Stützring Teflon -30 ... +150 ºC
 114660
Positioning ring (PPS)
 107397
Positioning ring without cam (PPS)
 107926
Positioning ring (metal)
 107383
Connection print (connector couterpart)
109225
Clam screw M20x1
 112151
Screw insert for clamp screw
 112187



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 




Huba Control Pressure measuring cell 509

Pressure measuring cell 509
0 ... 2.5 - 250 bar


Type 509 pressure measuring cells are based on ceramic technology developed by Huba Control, and used for the last 20 years in millions of applications. Due to the robust design of the ceramic cell there are no significant changes in the sensor characteristics when mounted by the customer. The pressure measuring cells are delivered either factory set or with TK zero point adjustment. You can choose between various versions as integrated temperature measurement. Fixed order quantities on request





Medium Liquids and gases
Pressure range 0 ... 2.5 – 250 bar
Nullpunkt 0.2 ± 0.2 mV / V
Spannung bei Nenndruck 2.5 ± 1.5 mV / V
Accuracy < 0.5% FS
Electrical connection Flexible connector RAST 2.54 mm,
bondpads (AgPd) RAST 1.27 mm,
pin-Conector

Negligible temperature influence on accuracy
No customer specific adjustment of zero point and temperature compensation necessary
Easy mounting
Overload secure up to rupture pressure

Accessories
O-Ring FPM -15 ... +125 ºC
105598
O-Ring NBR -25 ... + 85 ºC
105145
O-Ring FPM -30 ... +150 ºC
109338
O-Ring FPM -15 ... +125 ºC
105285
O-Ring NBR -25 ... + 85 ºC
104952
O-Ring FPM -30 ... +150 ºC
102321
Stützring Teflon -30 ... +150 ºC
114660
Clam screw M20x1
112151
Screw insert for clamp screw
112187



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 



Huba Control Vortex flow sensor 236

Flow sensor 236
0.9 ... 240 l/min

The difference between flow sensor type 236 and type 210 is the version of the case. The Vortex sensor type 236 has a rugged construction of brass connection. This flow sensor is available with a larger variety concerning power supply and outputs. You can choose between various versions as integrated temperature measurement. Type 236 without moving parts is insensitive to pollution and persuades by very few loss of pressure and a very high accuracy.




Medium 
Fluides
Flow range 
1.8 ... 240 l/min.
Nominal diameters 
DN 10 / 15 / 20 / 25 / 32
Output 
Frequency output 9 ... 479 Hz
Analogue signal 0 ... 10 V, 4 ... 20 mA
Temp. measurment 
PT1000
Electrical connection 
M12x1
Tube connection Brass - outside threa

Flow measuring with voltage, current, pulse or frequency output
Temperature non-sensitive measuring principle
Excellent media resistance (measuring element not in contact with the media)
Available with temperature measurement
Excellent EMC capacity by reinforcement on measuring cell
Measuring element not sensitive to debris
Direct temperature measurement in the medium
Drinking water approval





Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 

Huba Control Vortex flow sensor 235

OEM Flow sensor 235
0.9 ... 240 l/min

The difference between flow sensor type 235 and type 200 is the version of the case. The flow sensor type 235 is based on the Kármán vortex street. You can choose between various versions as integrated temperature measurement. This flow sensor without moving parts is insensitive to pollution and persuade by very few loss of pressure and a very high accuracy.






Medium 
Fluides
Flow range 
0.9 ... 240 l/min.
Nominal diameters 
DN 10 / 15 / 20 / 25 / 32
Output 
Frequency output 9 ... 479 Hz
Temp. measurment 
NTC / PT1000
Electrical connection 
Connector RAST 2.5, M12x1
Tube connectionBrass - outside thread

Low cost product with high levels of accuracy
Temperature non-sensitive measuring principle
Excellent media resistance (measuring element not in contact with the media)
Wide application temperature range
Marginal loss of pressure
Measuring element not sensitive to debris
Direct temperature measurement in the medium with PT1000 or NTC
Drinking water approval



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 

Huba Control Vortex flow sensor 230

Flow sensor 230
1.8 ... 150 l/min


The flow sensor type 230 is based on the Kármán vortex street. You can choose between various versions as integrated temperature measurement.  The type 230 has a rugged construction of red brass. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy.




Medium Fluides
Flow range 1.8 ... 150 l/min.
Nominal diameters DN 10 / 15 / 20 / 25
Output Frequency output 13 ... 480 Hz
                                                  Analogue signal 0 ... 10 V, 4 ... 20 mAA
Temp. measurment PT1000
Electrical connection M12x1
Tube connectionRed brass - outside thread

Flow measuring with voltage, current, pulse or frequency output

Excellent media resistance (measuring element not in contact with the media)

Available with integrated temperature measurement

Temperature non-sensitive measuring principle

Wide application temperature range

Marginal loss of pressure

Measuring element not sensitive to debris

Drinking water approval



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 

Huba Control Vortex flow sensor 212

Flow sensor 212 with display
0.5 ... 150 l/min



The flow sensor type 212 is based on the Kármán vortex trail. Vortex trail principle. This flow sensor convinces due to the additional digital indicating device which shows the flow rate and the media temperature. The type 212 is available with and without temperature measurement.

With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy.





Medium Fluides
Flow range 0.5 ... 150 l/min.
Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25
Output 4 ... 14.5 mA, 4 ... 20 mA
Electrical connection M12x1
Tube connectionPlastic - connection copper tube
Plastic - outside thread



Flow measuring with immediate display of flow measuring range and medium temperature

Excellent media resistance (measuring element not in contact with the media)

Available with integrated temperature measurement

CE conformityMarginal loss of pressure

Measuring element not sensitive to debris

Drinking water approval

Temperature non-sensitive measuring principle


Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia.