Tuesday, May 28, 2019

Huba Control Vortex flow sensor 236

Flow sensor 236
0.9 ... 240 l/min

The difference between flow sensor type 236 and type 210 is the version of the case. The Vortex sensor type 236 has a rugged construction of brass connection. This flow sensor is available with a larger variety concerning power supply and outputs. You can choose between various versions as integrated temperature measurement. Type 236 without moving parts is insensitive to pollution and persuades by very few loss of pressure and a very high accuracy.




Medium 
Fluides
Flow range 
1.8 ... 240 l/min.
Nominal diameters 
DN 10 / 15 / 20 / 25 / 32
Output 
Frequency output 9 ... 479 Hz
Analogue signal 0 ... 10 V, 4 ... 20 mA
Temp. measurment 
PT1000
Electrical connection 
M12x1
Tube connection Brass - outside threa

Flow measuring with voltage, current, pulse or frequency output
Temperature non-sensitive measuring principle
Excellent media resistance (measuring element not in contact with the media)
Available with temperature measurement
Excellent EMC capacity by reinforcement on measuring cell
Measuring element not sensitive to debris
Direct temperature measurement in the medium
Drinking water approval





Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 

Huba Control Vortex flow sensor 235

OEM Flow sensor 235
0.9 ... 240 l/min

The difference between flow sensor type 235 and type 200 is the version of the case. The flow sensor type 235 is based on the Kármán vortex street. You can choose between various versions as integrated temperature measurement. This flow sensor without moving parts is insensitive to pollution and persuade by very few loss of pressure and a very high accuracy.






Medium 
Fluides
Flow range 
0.9 ... 240 l/min.
Nominal diameters 
DN 10 / 15 / 20 / 25 / 32
Output 
Frequency output 9 ... 479 Hz
Temp. measurment 
NTC / PT1000
Electrical connection 
Connector RAST 2.5, M12x1
Tube connectionBrass - outside thread

Low cost product with high levels of accuracy
Temperature non-sensitive measuring principle
Excellent media resistance (measuring element not in contact with the media)
Wide application temperature range
Marginal loss of pressure
Measuring element not sensitive to debris
Direct temperature measurement in the medium with PT1000 or NTC
Drinking water approval



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 

Huba Control Vortex flow sensor 230

Flow sensor 230
1.8 ... 150 l/min


The flow sensor type 230 is based on the Kármán vortex street. You can choose between various versions as integrated temperature measurement.  The type 230 has a rugged construction of red brass. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy.




Medium Fluides
Flow range 1.8 ... 150 l/min.
Nominal diameters DN 10 / 15 / 20 / 25
Output Frequency output 13 ... 480 Hz
                                                  Analogue signal 0 ... 10 V, 4 ... 20 mAA
Temp. measurment PT1000
Electrical connection M12x1
Tube connectionRed brass - outside thread

Flow measuring with voltage, current, pulse or frequency output

Excellent media resistance (measuring element not in contact with the media)

Available with integrated temperature measurement

Temperature non-sensitive measuring principle

Wide application temperature range

Marginal loss of pressure

Measuring element not sensitive to debris

Drinking water approval



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 

Huba Control Vortex flow sensor 212

Flow sensor 212 with display
0.5 ... 150 l/min



The flow sensor type 212 is based on the Kármán vortex trail. Vortex trail principle. This flow sensor convinces due to the additional digital indicating device which shows the flow rate and the media temperature. The type 212 is available with and without temperature measurement.

With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy.





Medium Fluides
Flow range 0.5 ... 150 l/min.
Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25
Output 4 ... 14.5 mA, 4 ... 20 mA
Electrical connection M12x1
Tube connectionPlastic - connection copper tube
Plastic - outside thread



Flow measuring with immediate display of flow measuring range and medium temperature

Excellent media resistance (measuring element not in contact with the media)

Available with integrated temperature measurement

CE conformityMarginal loss of pressure

Measuring element not sensitive to debris

Drinking water approval

Temperature non-sensitive measuring principle


Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 






Huba Control Vortex flow sensor 210

Flow sensor 210
0.5 ... 150 l/min

In comparison to the OEM flow sensor (type 200) the type 210 is available with a larger variety concerning power supply and outputs. You can choose between various versions as integrated temperature measurement. This flow sensor without moving parts is  insensitive to pollution and persuade by very few loss of pressure and a very high accuracy.





Medium Fluides
Flow range 0.5 ... 150 l/min.
Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25
Output Frequency output 12 ... 483 Hz
                                                  Analogue signal 0 ... 10 V, 4 ... 20 mA
Temp. measurment PT1000, 0 ... 10 V
Electrical connection M12x1
Tube connectionPlastic - connection copper tube
Plastic - outside thread




Flow measuring with voltage, current, pulse or frequency output

Excellent media resistance (measuring element not in contact with the media)

Available with integrated temperature measurement

Temperature non-sensitive measuring principle

Wide application temperature range

Marginal loss of pressure

Measuring element not sensitive to debris

Drinking water approval


Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 








Huba Control Vortex flow sensor 200

OEM Flow sensor 200
0.5 ... 150 l/min


The vortex flow sensor type 200 is based on the Kármán vortex street. You can choose between various versions as integrated temperature measurement. This flow sensor without moving parts is insensitive to pollution and persuade by very few loss of pressure and a very high accuracy.
Fixed order quantities on request

Medium Fluides
Flow range 0.5 ... 150 l/min.
Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25
Output Frequency output 12 ... 483 Hz
Temp. measurment NTC / PT1000
Electrical connection Connector RAST 2.5, M12x1
Tube connectionPlastic - connection copper tube
Plastic - outside thread




Low cost product with high levels of accuracy

Temperature non-sensitive measuring principle

Excellent media resistance (measuring element not in contact with the media)

Marginal loss of pressure

Measuring element not sensitive to debris

Direct temperature measurement in the medium with PT1000 or NTC

Wide application temperature range

Drinking water approval




Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia. 










Huba Control Pressure level transmitter 713

Pressure level transmitter 713
0 ... 0.6 - 16 bar

The pressure level transmitter type 713 is used for continuous fluid level measurement of ground and drinking water. The compact design allows the transmitter to be used in applications with restricted access as small as 3/4 inch i.d. pipe. 
As well as a current output the pressure level transmitter type 713 has been enhanced with energy efficient ratiometric and digital outputs making it ideal for battery powered applications.
The pressure level sensor 713 is based upon the well proven ceramic technology developed by Huba Control over 20 years ago.




Medium Fluides
Pressure range 0 ... 0.6 - 16 bar
Output 4 ... 20 mA , ratiom. 10 ... 90%,3000 ... 11000 Digits
Accuracy < 0.3% fs
Electrical connectionCable in several lengths
Ceramic sensor Al2O3 99.6%
Continuous level measurement
Suitable for drinking water
Available with temperature measurement
Excellent linearity and long term stability
Applicable in 3/4 inch pipes

Accessories
Cable hanger
 118026
Connection box
 118027
Humidity protection element (pack of 10)
 118068
Calibration certificate
 104551



Contact: ken.sim@improtechonline.com
Mr.Ken Sim, Mobile: +6012-4661514


TECH IMPRO AUTOMATION SOLUTION SDN. BHD.
Address: 7263 (1st Floor), Lorong Chempa,
12200 Butterworth,
Penang, Malaysia.